NAME | SYNOPSIS | DESCRIPTION | OPTIONS | FILES | EXAMPLES | AUTHOR | COLOPHON |
|
|
|
IBCCQUERY(8) OpenIB Diagnostics IBCCQUERY(8)
IBCCQUERY - query congestion control settings/info
ibccquery [common_options] [-c cckey] <op> <lid|guid> [port]
ibccquery support the querying of settings and other information
related to congestion control.
Current supported operations and their parameters:
CongestionInfo (CI) <addr> CongestionKeyInfo (CK) <addr>
CongestionLog (CL) <addr> SwitchCongestionSetting (SS)
<addr> SwitchPortCongestionSetting (SP) <addr> [<portnum>]
CACongestionSetting (CS) <addr> CongestionControlTable (CT)
<addr> Timestamp (TI) <addr>
--cckey, -c <cckey> Specify a congestion control (CC) key. If
none is specified, a key of 0 is used.
Debugging flags
-d raise the IB debugging level. May be used several times
(-ddd or -d -d -d).
-e show send and receive errors (timeouts and others)
-h, --help show the usage message
-v, --verbose
increase the application verbosity level. May be used
several times (-vv or -v -v -v)
-V, --version show the version info.
Addressing Flags
-G, --Guid The address specified is a Port GUID
-L, --Lid The address specified is a LID
-s, --sm_port <smlid> use 'smlid' as the target lid for SA
queries.
Port Selection flags
-C, --Ca <ca_name> use the specified ca_name.
-P, --Port <ca_port> use the specified ca_port.
Local port Selection
Multiple port/Multiple CA support: when no IB device or port is
specified (see the "local umad parameters" below), the libibumad
library selects the port to use by the following criteria:
1. the first port that is ACTIVE.
2. if not found, the first port that is UP (physical link up).
If a port and/or CA name is specified, the libibumad library
attempts to fulfill the user request, and will fail if it is
not possible.
For example:
ibaddr # use the first port (criteria #1 above)
ibaddr -C mthca1 # pick the best port from "mthca1" only.
ibaddr -P 2 # use the second (active/up) port from the first available IB device.
ibaddr -C mthca0 -P 2 # use the specified port only.
Configuration flags
-y, --m_key <key>
use the specified M_key for requests. If non-numeric value
(like 'x') is specified then a value will be prompted for.
--config, -z <config_file> Specify alternate config file.
Default:
/ssd11/FOSS/rdma-core/build/etc/infiniband-diags/ibdiag.conf
CONFIG FILE
/ssd11/FOSS/rdma-core/build/etc/infiniband-diags/ibdiag.conf
A global config file is provided to set some of the common options
for all tools. See supplied config file for details.
ibccquery CongestionInfo 3 # Congestion Info by lid
ibccquery SwitchPortCongestionSetting 3 # Query all Switch Port Congestion Settings
ibccquery SwitchPortCongestionSetting 3 1 # Query Switch Port Congestion Setting for port 1
Albert Chu
< <[email protected]> >
This page is part of the rdma-core (RDMA Core Userspace Libraries
and Daemons) project. Information about the project can be found
at ⟨https://github.com/linux-rdma/rdma-core⟩. If you have a bug
report for this manual page, send it to
[email protected]. This page was obtained from the
project's upstream Git repository
⟨https://github.com/linux-rdma/rdma-core.git⟩ on 2025-08-11. (At
that time, the date of the most recent commit that was found in
the repository was 2025-08-04.) If you discover any rendering
problems in this HTML version of the page, or you believe there is
a better or more up-to-date source for the page, or you have
corrections or improvements to the information in this COLOPHON
(which is not part of the original manual page), send a mail to
[email protected]
2012-05-31 IBCCQUERY(8)